Zemic H2A Basma Load Cell TANK & SİLO UYGULAMASI
Zemic H2A Basma Load Cell TANK & SİLO UYGULAMASI
Product H2A Load Cell
Features H2A Load Cell:
- Alloy steel IP67 spoke type load cell.
- Surface flange treatment, spray paint, hermetically sealed.
|
Products specification |
◆H2A load cells are available in the manifold accurate
measurement in the capacities 1MN to 5MN.
◆Alloy steel,surface bluing treatment,spray painted,
oil-proof,waterproof and anti-corrosion,suitable for
groundsill measuring and other engineeringmeasuring fields.
◆Spoke type,easy installation,suitable for special force
measuring equipment.
◆Safety and anti-explosion product,can be used in atrocious
environments and hazardous areas. |
Important Features
◆Capacities:1MN~5MN.
◆Alloy steel construction.
◆High reliability and long life span. |
Specifications
Capacity
|
MN
|
1/2/3/4/5
|
Accuracy
|
|
G1
|
G2
|
G3
|
Combined error
|
(%FS)
|
0.1%
|
0.2%
|
0.3%
|
Creep
|
(%FS/30min)
|
0.05%
|
0.05%
|
0.05%
|
Temperature effect on sensitivity
|
(%FS/10℃)
|
0.05%
|
0.1%
|
0.2%
|
Temperature effect on zero
|
(%FS/10℃)
|
0.05%
|
0.1%
|
0.2%
|
Output sensitivity
|
(mv/v)
|
≥ 2.0
|
Input resistance
|
(Ω)
|
1072±5
|
Output resistance
|
(Ω)
|
1050±5
|
Insulation resistance
|
(MΩ)
|
≥ 5000(50VDC)
|
Zero balance
|
(%FS)
|
1.0
|
Temperature,compensated
|
(℃)
|
-10~+40
|
Temperature,operating
|
(℃)
|
-35~+65
|
Excitation,Recommended
|
(V)
|
5~12(DC)
|
Excitation,Max
|
(V)
|
18(DC)
|
Safe overload
|
(%FS)
|
150
|
Ultimate overload
|
(%FS)
|
300
|
Outline Dimension mm(inch)

Capacity(t)
|
100
|
200
|
300
|
400
|
500
|
D
|
59(2.32)
|
78(3.07)
|
91(3.58)
|
110 (4.33)
|
133 (5.24)
|
D1
|
260 (10.24)
|
290 (11.42)
|
330 (12.99)
|
400 (15.75)
|
400 (15.75)
|
D2
|
200(7.87)
|
225 (8.86)
|
251(9.88)
|
296(11.65)
|
307 (12.09)
|
H
|
80(3.15)
|
104(4.09)
|
123(4.84)
|
132(5.20)
|
132(5.20)
|
H1
|
10(0.39)
|
10(0.39)
|
10(0.39)
|
10(0.39)
|
10(0.39)
|
More detailed information about H2A
|